familyname=Stationary Decoder manufacturer=Team Digital, LLC definitionSource=JMRI LOCONETOPSBOARDCV=1,"Output 1 Address" CV=2,"On Time CV value" CV=3,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 1 Type" CV=4,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 2 Type" CV=5,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 3 Type" CV=6,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 4 Type" CV=7,"Version ID" CV=8,"Manufacturer ID" CV=10,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 5 Type" CV=11,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 6 Type" CV=12,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 7 Type" CV=13,","Solenoid","0Solenoid","Stall","1Stall","Pulse","2Pulse","Manual Control","4Manual Control"Output 8 Type" CV=14,"Output 2 Address" CV=16,"Output 3 Address" CV=18,"Output 4 Address" CV=20,"Output 5 Address" CV=22,"Output 6 Address" CV=24,"Output 7 Address" CV=26,"Output 8 Address" CV=28,"Power On Send Input State" CV=28,"Power On Send Output State" CV=28,"Interrogate input" CV=28,"Interrogate output" CV=29,","None","None","Option 1 - Use Power Off State","Option 1 - Use Power Off State","Option 2 - Use Set State","Option 2 - Use Set State"Select Power On Option" CV=29,"Option 3" CV=29,"DCC gateway" CV=29,"Bus interface" CV=29,"DCC control" CV=31,"Ops Mode Address" CV=33,","n","0n","t","1t","c","2c"" CV=33,","n","0n","t","1t","c","2c"" CV=33,","n","0n","t","1t","c","2c"" CV=33,","n","0n","t","1t","c","2c"" CV=34,","n","0n","t","1t","c","2c"" CV=34,","n","0n","t","1t","c","2c"" CV=34,","n","0n","t","1t","c","2c"" CV=34,","n","0n","t","1t","c","2c"" CV=35,"Address" CV=36,"Invert" CV=36,"Toggle" CV=36,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=37,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=37,"Route Number" CV=38,"Address" CV=39,"Invert" CV=39,"Toggle" CV=39,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=40,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=40,"Route Number" CV=41,"Address" CV=42,"Invert" CV=42,"Toggle" CV=42,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=43,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=43,"Route Number" CV=44,"Address" CV=45,"Invert" CV=45,"Toggle" CV=45,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=46,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=46,"Route Number" CV=47,"Address" CV=48,"Invert" CV=48,"Toggle" CV=48,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=49,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=49,"Route Number" CV=50,"Address" CV=51,"Invert" CV=51,"Toggle" CV=51,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=52,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=52,"Route Number" CV=53,"Address" CV=54,"Invert" CV=54,"Toggle" CV=54,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=55,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=55,"Route Number" CV=56,"Address" CV=57,"Invert" CV=57,"Toggle" CV=57,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=58,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=58,"Route Number" CV=59,"Address" CV=60,"Invert" CV=60,"Toggle" CV=60,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=61,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=61,"Route Number" CV=62,"Address" CV=63,"Invert" CV=63,"Toggle" CV=63,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=64,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=64,"Route Number" CV=65,"Address" CV=66,"Invert" CV=66,"Toggle" CV=66,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=67,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=67,"Route Number" CV=68,"Address" CV=69,"Invert" CV=69,"Toggle" CV=69,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=70,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=70,"Route Number" CV=71,"Address" CV=72,"Invert" CV=72,"Toggle" CV=72,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=73,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=73,"Route Number" CV=74,"Address" CV=75,"Invert" CV=75,"Toggle" CV=75,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=76,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=76,"Route Number" CV=77,"Address" CV=78,"Invert" CV=78,"Toggle" CV=78,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=79,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=79,"Route Number" CV=80,"Address" CV=81,"Invert" CV=81,"Toggle" CV=81,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=82,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=82,"Route Number" CV=83,"Address" CV=84,"Invert" CV=84,"Toggle" CV=84,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=85,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=85,"Route Number" CV=86,"Address" CV=87,"Invert" CV=87,"Toggle" CV=87,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=88,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=88,"Route Number" CV=89,"Address" CV=90,"Invert" CV=90,"Toggle" CV=90,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=91,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=91,"Route Number" CV=92,"Address" CV=93,"Invert" CV=93,"Toggle" CV=93,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=94,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=94,"Route Number" CV=95,"Address" CV=96,"Invert" CV=96,"Toggle" CV=96,","Switch Request","Switch Request","Switch Feedback","Switch Feedback","Sensor Message","Sensor Message"Type" CV=97,","No Message","No Message","Send on Rising Edge","Send on Rising Edge","Send on Falling Edge","Send on Falling Edge","Send on Both Edges","Send on Both Edges"Transition" CV=97,"Route Number" CV=98,"Output busy timer" CV=99,"Route send delay" CV=100,"Address" CV=112,"Top Address" CV=113,","t","t","c","c"Switch State" CV=113,","No","0No","Yes","2Yes"Sensor Route Execution" CV=114,"Top Address" CV=115,","t","t","c","c"Switch State" CV=115,","No","0No","Yes","2Yes"Sensor Route Execution" CV=116,"Top Address" CV=117,","t","t","c","c"Switch State" CV=117,","No","0No","Yes","2Yes"Sensor Route Execution" CV=118,"Top Address" CV=119,","t","t","c","c"Switch State" CV=119,","No","0No","Yes","2Yes"Sensor Route Execution" CV=120,"Top Address" CV=121,","t","t","c","c"Switch State" CV=121,","No","0No","Yes","2Yes"Sensor Route Execution" CV=122,"Top Address" CV=123,","t","t","c","c"Switch State" CV=123,","No","0No","Yes","2Yes"Sensor Route Execution" CV=124,"Top Address" CV=125,","t","t","c","c"Switch State" CV=125,","No","0No","Yes","2Yes"Sensor Route Execution" CV=126,"Top Address" CV=127,","t","t","c","c"Switch State" CV=127,","No","0No","Yes","2Yes"Sensor Route Execution" CV=128,"Cell 1 Address" CV=129,","t","t","c","c"Switch State" CV=130,"Cell 2 Address" CV=131,","t","t","c","c"Switch State" CV=132,"Cell 3 Address" CV=133,","t","t","c","c"Switch State" CV=134,"Cell 4 Address" CV=135,","t","t","c","c"Switch State" CV=136,"Cell 5 Address" CV=137,","t","t","c","c"Switch State" CV=138,"Cell 6 Address" CV=139,","t","t","c","c"Switch State" CV=140,"Cell 7 Address" CV=141,","t","t","c","c"Switch State" CV=142,"Cell 8 Address" CV=143,","t","t","c","c"Switch State" CV=144,"Cell 1 Address" CV=145,","t","t","c","c"Switch State" CV=146,"Cell 2 Address" CV=147,","t","t","c","c"Switch State" CV=148,"Cell 3 Address" CV=149,","t","t","c","c"Switch State" CV=150,"Cell 4 Address" CV=151,","t","t","c","c"Switch State" CV=152,"Cell 5 Address" CV=153,","t","t","c","c"Switch State" CV=154,"Cell 6 Address" CV=155,","t","t","c","c"Switch State" CV=156,"Cell 7 Address" CV=157,","t","t","c","c"Switch State" CV=158,"Cell 8 Address" CV=159,","t","t","c","c"Switch State" CV=160,"Cell 1 Address" CV=161,","t","t","c","c"Switch State" CV=162,"Cell 2 Address" CV=163,","t","t","c","c"Switch State" CV=164,"Cell 3 Address" CV=165,","t","t","c","c"Switch State" CV=166,"Cell 4 Address" CV=167,","t","t","c","c"Switch State" CV=168,"Cell 5 Address" CV=169,","t","t","c","c"Switch State" CV=170,"Cell 6 Address" CV=171,","t","t","c","c"Switch State" CV=172,"Cell 7 Address" CV=173,","t","t","c","c"Switch State" CV=174,"Cell 8 Address" CV=175,","t","t","c","c"Switch State" CV=176,"Cell 1 Address" CV=177,","t","t","c","c"Switch State" CV=178,"Cell 2 Address" CV=179,","t","t","c","c"Switch State" CV=180,"Cell 3 Address" CV=181,","t","t","c","c"Switch State" CV=182,"Cell 4 Address" CV=183,","t","t","c","c"Switch State" CV=184,"Cell 5 Address" CV=185,","t","t","c","c"Switch State" CV=186,"Cell 6 Address" CV=187,","t","t","c","c"Switch State" CV=188,"Cell 7 Address" CV=189,","t","t","c","c"Switch State" CV=190,"Cell 8 Address" CV=191,","t","t","c","c"Switch State" CV=192,"Cell 1 Address" CV=193,","t","t","c","c"Switch State" CV=194,"Cell 2 Address" CV=195,","t","t","c","c"Switch State" CV=196,"Cell 3 Address" CV=197,","t","t","c","c"Switch State" CV=198,"Cell 4 Address" CV=199,","t","t","c","c"Switch State" CV=200,"Cell 5 Address" CV=201,","t","t","c","c"Switch State" CV=202,"Cell 6 Address" CV=203,","t","t","c","c"Switch State" CV=204,"Cell 7 Address" CV=205,","t","t","c","c"Switch State" CV=206,"Cell 8 Address" CV=207,","t","t","c","c"Switch State" CV=208,"Cell 1 Address" CV=209,","t","t","c","c"Switch State" CV=210,"Cell 2 Address" CV=211,","t","t","c","c"Switch State" CV=212,"Cell 3 Address" CV=213,","t","t","c","c"Switch State" CV=214,"Cell 4 Address" CV=215,","t","t","c","c"Switch State" CV=216,"Cell 5 Address" CV=217,","t","t","c","c"Switch State" CV=218,"Cell 6 Address" CV=219,","t","t","c","c"Switch State" CV=220,"Cell 7 Address" CV=221,","t","t","c","c"Switch State" CV=222,"Cell 8 Address" CV=223,","t","t","c","c"Switch State" CV=224,"Cell 1 Address" CV=225,","t","t","c","c"Switch State" CV=226,"Cell 2 Address" CV=227,","t","t","c","c"Switch State" CV=228,"Cell 3 Address" CV=229,","t","t","c","c"Switch State" CV=230,"Cell 4 Address" CV=231,","t","t","c","c"Switch State" CV=232,"Cell 5 Address" CV=233,","t","t","c","c"Switch State" CV=234,"Cell 6 Address" CV=235,","t","t","c","c"Switch State" CV=236,"Cell 7 Address" CV=237,","t","t","c","c"Switch State" CV=238,"Cell 8 Address" CV=239,","t","t","c","c"Switch State" CV=240,"Cell 1 Address" CV=241,","t","t","c","c"Switch State" CV=242,"Cell 2 Address" CV=243,","t","t","c","c"Switch State" CV=244,"Cell 3 Address" CV=245,","t","t","c","c"Switch State" CV=246,"Cell 4 Address" CV=247,","t","t","c","c"Switch State" CV=248,"Cell 5 Address" CV=249,","t","t","c","c"Switch State" CV=250,"Cell 6 Address" CV=251,","t","t","c","c"Switch State" CV=252,"Cell 7 Address" CV=253,","t","t","c","c"Switch State" CV=254,"Cell 8 Address" CV=255,","t","t","c","c"Switch State" ------ SMD84 Output Addresses ------ Use this number to set the address numberof the turnout the output is connected to.------ Notes: ------ The Custom Programmer format is recommendedBasicNote: Changes to Option CVs are not recognized until SMD84 power is cycled.------ Decoder Configuration CV29 ------ ------ Communication Options ------ Opt4 Enable gateway for DCC commands from track to bus- Requires bus interface and DCC control to be enabledOpt5 Enable transmit and receive on busOpt6 Enable receiving DCC commands from track- When disabled, DCC gateway is disabledNote: In a Digitrax system the bus is called LocoNet------ Special Options ------ Opt3 Enable operations mode programmingThis is the same as a Loco address------ Status Report CV28 ------ ------ Options ------ Opt1 Send input state at power on- Only sensor type inputsOpt2 Send output state at power on- Switch type messagesOpt3 Send primary input state at Digitrax interrogation request- Only sensor type inputsOpt4 Send output state at Digitrax interrogation request- Feedback type messagesOptionsMfg------ Primary Input 1 ------ ------ Primary Input 2 ------ ------ Primary Input 3 ------ ------ Primary Input 4 ------ ------ Primary Input 5 ------ ------ Primary Input 6 ------ ------ Primary Input 7 ------ ------ Primary Input 8 ------ Primary Inputs------ Secondary Input 1 ------ ------ Secondary Input 2 ------ ------ Secondary Input 3 ------ ------ Secondary Input 4 ------ ------ Secondary Input 5 ------ ------ Secondary Input 6 ------ ------ Secondary Input 7 ------ ------ Secondary Input 8 ------ Secondary Inputs------ Auxiliary Input 1 ------ ------ Auxiliary Input 2 ------ ------ Auxiliary Input 3 ------ ------ Auxiliary Input 4 ------ ------ Auxiliary Input 5 ------ Auxiliary InputsWhen a switch (turnout) throw command is issued that matches this address the SMD84 primary inputs are disabled.When a close command is issued with this address the primary inputs are enabled.This feature is useful for dispatcher control when the SMD84 primary inputs are used for local turnout control. Input lockout addressInput Lockout---- Output Configuration ---- Sets the pulse length for outputs configured as Pulse Duration in seconds = CV value times .256 The default value of 31 gives about 8 seconds---- Power On Output State ---- Output# NoneThrow (Reverse) Close (Normal) 1 2 3 4 5 6 7 8 Sets the output state to always be the same at power on Only applies if Option 2 is selectedOutputsNote: If a sensor message is selected to execute a route thenswitch state c and t is used for sensor hi and lo respectively.------ Route 1 ------ ------ Route 2 ------ ------ Route 3 ------ ------ Route 4 ------ ------ Route 5 ------ ------ Route 6 ------ ------ Route 7 ------ ------ Route 8 ------ RoutesCVs