familyname=DS64 manufacturer=Digitrax definitionSource=JMRI LOCONETBDOPSWMODECV=1,"Board ID" CV=115.01,","","Outputs are pulsed (OpSw1=t)Thrown is first choice; Closed is second choice","","Outputs are static (OpSw1=c)Thrown is first choice; Closed is second choice"" CV=115.02,","","Outputs pulse active or blink for 0.1 second (OpSw2=t)","","Outputs pulse active or blink for 0.2 second (OpSw2=c)"" CV=115.03,","","Add 0 seconds to the pulse or blink rate (OpSw3=t)","","Add 0.3 seconds to the pulse or blink rate (OpSw3=c)"" CV=115.04,","","Add 0 seconds to the pulse or blink rate (OpSw4=t)","","Add 0.7 seconds to the pulse or blink rate (OpSw4=c)"" CV=115.05,","","Add 0 seconds to the pulse or blink rate (OpSw5=t)","","Add 1.5 seconds to the pulse or blink rate (OpSw5=c)"" CV=115.06,","","Outputs automatically power-up to the last known state (OpSw6=t)Thrown is first choice; Closed is second choice","","Each output remain undriven until its turnout command is received (OpSw6=c)Thrown is first choice; Closed is second choice"" CV=115.08,","","Short delay for interrogation requests (OpSw8=t)Thrown is first choice; Closed is second choice","","Long delay for interrogation requests (OpSw8=c)Thrown is first choice; Closed is second choice"" CV=115.09,","","Static Outputs remain powered (OpSw9=t)Thrown is first choice; Closed is second choice","","Static Outputs are shut off after 16 seconds (OpSw9=c)Thrown is first choice; Closed is second choice"" CV=115.10,","","Throttle and Computer commands are accepted (OpSw10=t)Thrown is first choice; Closed is second choice","","Computer commands are accepted (OpSw10=c)Thrown is first choice; Closed is second choice"" CV=115.11,","","Routes are triggered by Switch commands from Computers or Throttles (OpSw11=t)Thrown is first choice; Closed is second choice","","Routes are triggered by DS64 inputs (OpSw11=c)Thrown is first choice; Closed is second choice"" CV=115.12,","","S inputs affect output; A inputs send Sensor messages (OpSw12=t)Thrown is first choice; Closed is second choice","","A input high forces output "Thrown"; S input high forces output "Closed" (OpSw12 = c)Thrown is first choice; Closed is second choice"" CV=115.13,","","Inputs have no effect (OpSw13=t)Thrown is first choice; Closed is second choice","","Inputs act as LocoNet Sensors and also control related outputs per OpSw12 (OpSw13=c)Thrown is first choice; Closed is second choice"" CV=115.14,","","Accepts commands from LocoNet messages and Track (OpSw14=t)Thrown is first choice; Closed is second choice","","Accepts commands from Track only (OpSw14=c)Thrown is first choice; Closed is second choice"" CV=115.15,","","Inputs can control outputs (OpSw15=t)Thrown is first choice; Closed is second choice","","Inputs have no direct effect on outputs (OpSw15=c)Thrown is first choice; Closed is second choice"" CV=115.16,"Routes are" CV=115.17,","","Output 1 does not provide "crossing-gate" output (OpSw17=t)Thrown is first choice; Closed is second choice","","Output 1 provides "crossing-gate" output (OpSw17=c)Thrown is first choice; Closed is second choice"" CV=115.18,","","Output 2 does not provide "crossing-gate" output (OpSw18=t)Thrown is first choice; Closed is second choice","","Output 2 provides "crossing-gate" output (OpSw18=c)Thrown is first choice; Closed is second choice"" CV=115.19,","","Output 3 does not provide "crossing-gate" output (OpSw19=t)Thrown is first choice; Closed is second choice","","Output 3 provides "crossing-gate" output (OpSw19=c)Thrown is first choice; Closed is second choice"" CV=115.20,","","Output 4 does not provide "crossing-gate" output (OpSw20=t)Thrown is first choice; Closed is second choice","","Output 4 provides "crossing-gate" output (OpSw20=c)Thrown is first choice; Closed is second choice"" CV=115.21,","","Inputs generate LocoNet "General Sensor" messages (OpSw21=t)Thrown is first choice; Closed is second choice","","Inputs generate LocoNet "LocoNet Turnout State" messages (OpSw21=c)Thrown is first choice; Closed is second choice"" CV=,"Outputs pulse or blink at " CV=,"DS64 Routes" CV=,"Local Inputs" CV=,"" OpSwsShort Addressgt0The "CV" column in the table above shows "OpSw" numbers, where the value "115." is pre-pended

to the OpSw Number. For example, PM4/PM42 OpSw 1 is represented as "115.01".

The top-most row above reflects the Board Address configured on the "Basic" sheet.

OpSw value 0 = "T"hrown. OpSw value 1 = "C"losed. Basic

LocoNet messaging limits the supported Board ID range to addresses between 1 and 128. This tool cannot access DS64s

outside of this range.

This roster entry will only access the specified DS64 if the Board ID, on the "Basic" sheet, is correct when the

programmer is opened.

If the Board ID has been changed since the programmer was opened, the programmer will attempt to access the

DS64 address which was specified in the Roster entry when the progammer was opened.

After making a change to the Roster entry's Board ID (Active Address) on the "Basic" sheet, save and close the programmer

window and re-open the Roster entry to ensure that the the programmer will use the modified Active Address for accesses

to the device.

Note that BDL16x and PM4x documentation refers to Board Address, while DS64 and SE8C documentation refers to

Board ID. These are equivalent concepts. DS64 Basic Settings

Output Controls Characteristics

Control Source Characteristics

Local Routes Characteristics

Local Input Signals Characteristics

Notes

Notes on DS64 Roster Entries and Programming

  • The DS64 must be in its normal operating mode in order to respond to this Roster entry's read and write operations.
  • See the "Basic" sheet for the programmer's limitations with respect to Board ID.

  • This Roster entry is not currently capable of displaying, changing, or saving the DS64 output addresses.

  • This Roster entry is not currently capable of displaying, changing, or saving the DS64 Routes.

CVsCVCV-TabelleTaula-CVTabulka CVCV-tabelShort Addresseq0This sheet intentionally un-populated. See the "OpSws" tab.