Options
Note: Changes to Option CVs are not recognized until SRC16 power is cycled.
------ Decoder Configuration CV9 ------
------ Communication Options ------
Opt4 Enable gateway for DCC commands from track to bus
- Requires bus interface and DCC control to be enabled
Opt5 Enable transmit and receive on bus
Opt6 Enable receiving DCC commands from track
- When disabled, DCC gateway is disabled
Note: In a Digitrax system the bus is called LocoNet
------ Special Options ------
Opt3 Enable operations mode programming
This is the same as a Loco address
Opt7 Output disabled when corresponding input grounded
Opt8 Enable to invert the drive for all outputs
------ Status Report CV10 ------
------ Options ------
Opt1 Send input state at power on
- Only sensor type inputs
Opt2 Send output state at power on
- Switch type messages
Opt5 Send primary input state at Digitrax interrogation request
- Only sensor type inputs
Opt4 Send output state at Digitrax interrogation request
Opt5 Send 16 output state at power on
- Requires Opt2
Options
Mfg
------ Input 1 ------
------ Input 2 ------
------ Input 3 ------
------ Input 4 ------
------ Input 5 ------
------ Input 6 ------
------ Input 7 ------
------ Input 8 ------
Inputs 1-8
------ Input 9 ------
------ Input 10 ------
------ Input 11 ------
------ Input 12 ------
------ Input 13 ------
------ Input 14 ------
------ Input 15 ------
------ Input 16 ------
Inputs 9-16
When a switch (turnout) throw command is issued that matches this address the SRC16 inputs are disabled.
When a close command is issued with this address the inputs are enabled.
This feature is useful for dispatcher control when the SRC16 inputs are used for local turnout control.
Input lockout address
Input Lockout
To form a group set both outputs to the same address with one to throw and the other to close.
Note: If a sensor message is selected then switch state c and t is used for sensor hi and lo respectively.
------ Output 1 ------
Output 1 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 2 ------
Output 2 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 3 ------
Output 3 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 4 ------
Output 4 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 5 ------
Output 5 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 6 ------
Output 6 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 7 ------
Output 7 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 8 ------
Output 8 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
Outputs 1-8
To form a group set both outputs to the same address with one to throw and the other to close.
Note: If a sensor message is selected then switch state c and t is used for sensor hi and lo respectively.
------ Output 9 ------
Output 9 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 10 ------
Output 10 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 11 ------
Output 11 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 12 ------
Output 12 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 13 ------
Output 13 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 14 ------
Output 14 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 15 ------
Output 15 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
------ Output 16 ------
Output 16 Control ---
Do not use for Bi-Color LEDs
Use for alternating flashing LEDs
Outputs 9-16
---- Power On Output State ----
Use for group outputs
Output#
None
Throw (Reverse)
Close (Normal)
1
2
3
4
5
6
7
8
Sets the output state to always be the same at power on
Only applies if Option 2 is selected
Use for single outputs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power On Outputs
Note: If a sensor message is selected to execute a route then
switch state c and t is used for sensor hi and lo respectively.
------ Route 1 ------
------ Route 2 ------
------ Route 3 ------
------ Route 4 ------
------ Route 5 ------
------ Route 6 ------
------ Route 7 ------
------ Route 8 ------
Routes
CVs