------ SMD84 Output Addresses ------
Use this number to set the address number
of the turnout the output is connected to.
------ Notes: ------
The Custom Programmer format is recommended
Basic
Note: Changes to Option CVs are not recognized until SMD84 power is cycled.
------ Decoder Configuration CV29 ------
------ Communication Options ------
Opt4 Enable gateway for DCC commands from track to bus
- Requires bus interface and DCC control to be enabled
Opt5 Enable transmit and receive on bus
Opt6 Enable receiving DCC commands from track
- When disabled, DCC gateway is disabled
Note: In a Digitrax system the bus is called LocoNet
------ Special Options ------
Opt3 Enable operations mode programming
This is the same as a Loco address
------ Status Report CV28 ------
------ Options ------
Opt1 Send input state at power on
- Only sensor type inputs
Opt2 Send output state at power on
- Switch type messages
Opt3 Send primary input state at Digitrax interrogation request
- Only sensor type inputs
Opt4 Send output state at Digitrax interrogation request
- Feedback type messages
Options
Mfg
------ Primary Input 1 ------
------ Primary Input 2 ------
------ Primary Input 3 ------
------ Primary Input 4 ------
------ Primary Input 5 ------
------ Primary Input 6 ------
------ Primary Input 7 ------
------ Primary Input 8 ------
Primary Inputs
------ Secondary Input 1 ------
------ Secondary Input 2 ------
------ Secondary Input 3 ------
------ Secondary Input 4 ------
------ Secondary Input 5 ------
------ Secondary Input 6 ------
------ Secondary Input 7 ------
------ Secondary Input 8 ------
Secondary Inputs
------ Auxiliary Input 1 ------
------ Auxiliary Input 2 ------
------ Auxiliary Input 3 ------
------ Auxiliary Input 4 ------
------ Auxiliary Input 5 ------
Auxiliary Inputs
When a switch (turnout) throw command is issued that matches this address the SMD84 primary inputs are disabled.
When a close command is issued with this address the primary inputs are enabled.
This feature is useful for dispatcher control when the SMD84 primary inputs are used for local turnout control.
Input lockout address
Input Lockout
---- Output Configuration ----
Sets the pulse length for outputs configured as Pulse
Duration in seconds = CV value times .256
The default value of 31 gives about 8 seconds
---- Power On Output State ----
Output#
None
Throw (Reverse)
Close (Normal)
1
2
3
4
5
6
7
8
Sets the output state to always be the same at power on
Only applies if Option 2 is selected
Outputs
Note: If a sensor message is selected to execute a route then
switch state c and t is used for sensor hi and lo respectively.
------ Route 1 ------
------ Route 2 ------
------ Route 3 ------
------ Route 4 ------
------ Route 5 ------
------ Route 6 ------
------ Route 7 ------
------ Route 8 ------
Routes
CVs