From NCE 2007 (with some minor corrections, formatting and additional info):
I've added two new binary commands on the Power Cab. They are for OPs programming of locomotives and OPs programming of accessories/signals The commands are 0xAE and 0xAF.
The USB interface when configured for Power Cab Ver 1.28 returns software version 6.3.0. When configured for the SB3 V1.28 it returns version 6.3.1. (SB3 doesn't have a program track) And when configured for the Power Pro 2007 it returns version 6.3.2. Not all binary commands are useful or available with the PowerCab, SB3, or Power Pro. PowerCab/SB3/Power Pro commands supported below:
*************************************************************************
The RS-232 port binary commands are designed to work in a computer friendly mode.
Command format is: (cmd number) (data) (data) ...
Commands range from 0x80 to 0xBF
The number of bytes in the command is determined by using the lookup table "BIN_TABLE". the number returned from the table is inclusive of the command number.
Commands and formats supported:
CMD FORMAT DESCRIPTION # OF BYTES RESPONSES RETURNED
--------------------------------------------------------------------------
0x80 NOP, dummy instruction (1) !
--------------------------------------------------------------------------
0x8C Dummy instruction returns "!" (3) !,0x0D,0x0A followed by CR/LF
--------------------------------------------------------------------------
0x9C xx Execute macro number xx (1) !,0,3
--------------------------------------------------------------------------
0x9E Enter Programming track mode (1) ! = success 3 = short circuit. Not supported by SB3 or PH
--------------------------------------------------------------------------
0x9F Exit Programming track mode (1) ! = success. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA0 aaaa xx Program CV aa with data xx in (1) ! = success paged mode 0 = program track not enabled. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA1 aaaa Read CV aa in paged mode (2) !,0,3 NOTE: cv data followed ! for ok, 0xff followed by 3 for can't read. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA2 (4 data bytes) Locomotive control command (1) !,1.
Sends a speed or function packet to a locomotive. Command Format: 0xA2 (addr_h) (addr_l) (op_1) (data_1)
addr_h and addr_l are the loco address in DCC format. If a long address is in use, bits 6 and 7 of the high byte are set. Ex: Long address 3 = 0xc0 0x03 Short address 3 = 0x00 0x03
op_1 data_1 Operation description
00 0-7f nop
01 0-7f Reverse 28 speed command
02 0-7f Forward 28 speed command
03 0-7f Reverse 128 speed command
04 0-7f Forward 128 speed command
05 0 Estop reverse command
06 0 Estop forward command
07 0-1f Function group 1 (same format as DCC packet for FG1)
08 0-0f Function group 2 (same format as DCC packet for FG2)
09 0-0f Function group 3 (same format as DCC packet for FG3)
0a-14 not supported in PowerCab or SB3 version 1.28
15 0-ff Functions 13-20 control (bit 0=F13, bit 7=F20)
16 0-ff Functions 21-28 control (bit 0=F21, bit 7=F28)
17-7f reserved reserved
--------------------------------------------------------------------------
0xA6 rr xx Program register rr with data xx (1) ! = success in register mode 0 = program track not enabled. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA7 rr Read register rr in register mode(2) !,3 NOTE: cv data followed ! for ok, 0 = program track not enabled 0xff followed by 3 for can't read. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA8 aaaa xx Program CV aaaa with data xx (1) ! = success in direct mode 0 = program track not enabled. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xA9 aaaa Read CV aaaa in direct mode (2) !,3 NOTE: cv data followed ! for ok, 0 = program track not enabled 0xff followed by 3 for can't read. Not supported by SB3 or PH
--------------------------------------------------------------------------
0xAA Return software revision number (3) (data1),(data2),(data3) FORMAT: VV.MM.mm
--------------------------------------------------------------------------
0xAD <4 data bytes>
Accy/signal and macro commands (1) !,1
Command Format: 0xAD (addr_h) (addr_l) (op_1) (data_1)
addr_h and addr_l are the accessory/signal address (NOT in DCC format). Ex: Accessory Address 513 = 0x02 0x01 (hi byte first)
NOTE: accy/signal address 0 is not a valid address
SPECIAL NOTE: PowerCab/SB3 version 1.28 only supports up to accessory address 250
Op_1 Data_1 Operation description
01 0-255 NCE macro number 0-255
02 0-255 Duplicate of Op_1 command
03 0 Accessory Normal direction (ON)
04 0 Accessory Reverse direction (OFF)
05 0-1f Signal Aspect 0-31
05-7f reserved reserved
--------------------------------------------------------------------------
0xAE (5 data bytes) OPs program loco CV (1) !,1,3. Not supported by PH
Command Format: 0xAE (addr_h) (addr_l) (CV_h) (CV_l) (data)
addr_h,addr_l are loco address (same as 0xA2 command) CV_h, CV_l are cv address high byte first data is 8 bit data for CV
--------------------------------------------------------------------------
0xAF <5 data bytes>
OPs program accessory/signal (1) !,1,3. Not
supported by PH
Command Format: 0xAF (addr_h) (addr_l) (CV_h) (CV_l) (data)
addr_h,addr_l are accy/sig address (same as 0xAD command) CV_h, CV_l are CV address high byte first data is 8 bit data for CV
--------------------------------------------------------------------------
NOTE: a single byte of 0 will be returned if not in programming mode for commands 0x9F,0xA0,0xA1 and 0xA6-0xA9
Errors returned:
'0'= command not supported
'1'= loco/accy/signal address out of range
'2'= cab address or op code out of range
'3'= CV address or data out of range
'4'= byte count out of range
'!'= command completed successfully
*************************************************************************
Commands not supported by USB, will return ASCII '0':
0x81 through 0x8B
0x8D through 0x9B
0x9D
0xA3 through 0xA5
0xAB, 0xAC
0xB2 through 0xBF
-
Constructor Summary
Constructors Constructor Description NceUSB()
Deprecated. -
Method Summary