<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE digitrax-cs-config SYSTEM "digitrax-cs-config.dtd">

<digitrax-cs-config>

  <command-station name="DCS50" >
    <!-- OpSws and Settings that uniquely identify this Command Station -->
    <identifier>
      <opsw number="59" setting="closed"/>
      <opsw number="60" setting="thrown"/>
      <opsw number="61" setting="thrown"/>
    </identifier>

    <!-- Configureable Options for a DCS50 -->
    <options>
    </options>
  </command-station>

  <command-station name="DCS100" >
    <!-- OpSws and Settings that uniquely identify this Command Station -->
    <identifier>
      <opsw number="59" setting="thrown"/>
      <opsw number="60" setting="closed"/>
      <opsw number="61" setting="closed"/>
    </identifier>

    <!-- Configureable Options for a DCS100 -->
    <options>
	<group name="Device" >
        <option name="Use this Command Station as a" >
          <choice name="Power Booster">
            <opsw number="5" setting="thrown"/>
          </choice>
          <choice name="Command Station">
            <opsw number="5" setting="closed"/>
          </choice>
        </option>

        <option name="Booster Auto Reversing" >
          <choice name="Disabled">
            <opsw number="3" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="3" setting="closed"/>
          </choice>
        </option>

        <option name="Booster Short Circuit Shutdown after" >
          <choice name="125ms">
            <opsw number="18" setting="thrown"/>
          </choice>
          <choice name="500ms">
            <opsw number="18" setting="closed"/>
          </choice>
        </option>

        <option name="Number of Locomotive Slots" >
          <choice name="22 (Big Boy Compatible">
            <opsw number="44" setting="thrown"/>
          </choice>
          <choice name="120">
            <opsw number="44" setting="closed"/>
          </choice>
        </option>

        <option name="Programming Track Brake Generator" >
          <choice name="Disabled">
            <opsw number="47" setting="thrown"/>
          </choice>
          <choice name="Enabled while not Programming">
            <opsw number="47" setting="closed"/>
          </choice>
        </option>

        <option name="Restore Track Power to Prior State at Power Up" >
          <choice name="Disabled">
            <opsw number="33" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="33" setting="closed"/>
          </choice>
        </option>

        <option name="Restore Track Power to Run State at Power Up" >
          <choice name="Disabled">
            <opsw number="34" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="34" setting="closed"/>
          </choice>
        </option>
      </group>

      <group name="Switches" >
        <option name="Command Station Switch State Reply" >
          <choice name="Enabled">
            <opsw number="45" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="45" setting="closed"/>
          </choice>
        </option>

        <option name="Switch Routes" >
          <choice name="Disabled">
            <opsw number="26" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="26" setting="closed"/>
          </choice>
        </option>

        <option name="Meter Switch/Route Output Rate" >
          <choice name="Disabled">
            <opsw number="31" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="31" setting="closed"/>
          </choice>
        </option>

        <option name="Command Station Execution of Switch Commands" >
          <choice name="Enabled">
            <opsw number="27" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="27" setting="closed"/>
          </choice>
        </option>
      </group>

      <group name="LocoNet" >
        <option name="Command Station Track Status Update" >
          <choice name="Enabled">
            <opsw number="43" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="43" setting="closed"/>
          </choice>
        </option>

        <option name="Interrogate DS54 States on Power Up" >
          <choice name="Enabled">
            <opsw number="28" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="28" setting="closed"/>
          </choice>
        </option>

        <option name="Command Station Valid LocoNet Message Received Clicks" >
          <choice name="Disabled">
            <opsw number="41" setting="thrown"/>
          </choice>
          <choice name="Enabled">
            <opsw number="41" setting="closed"/>
          </choice>
        </option>
      </group>

      <group name="Motorola Trinary" >
        <option name="Motorola Trinary Loco Addresses" >
          <choice name="Disabled">
            <opsw number="12" setting="thrown"/>
          </choice>
          <choice name="1-80 Enabled (status edit to x1)">
            <opsw number="12" setting="closed"/>
          </choice>
        </option>

        <option name="Motorola Trinary Switch Command Echo" >
          <choice name="Disabled">
            <opsw number="9" setting="thrown"/>
            <opsw number="10" setting="thrown"/>
          </choice>
          <choice name="1-64">
            <opsw number="9" setting="closed"/>
            <opsw number="10" setting="thrown"/>
          </choice>
          <choice name="1-256">
            <opsw number="9" setting="closed"/>
            <opsw number="10" setting="closed"/>
          </choice>
        </option>

        <option name="Motorola Trinary Switchs 57-64 ON Period" >
          <choice name="Normal - Pulse">
            <opsw number="11" setting="thrown"/>
          </choice>
          <choice name="Long - 1 second">
            <opsw number="11" setting="closed"/>
          </choice>
        </option>
      </group>

      <group name="Locomotives" >
        <option name="Global System Default Type for New Locos" >
          <choice name="128 Step mode">
            <opsw number="21" setting="thrown"/>
            <opsw number="22" setting="thrown"/>
            <opsw number="23" setting="thrown"/>
          </choice>
          <choice name="128 Step FX mode">
            <opsw number="21" setting="thrown"/>
            <opsw number="22" setting="thrown"/>
            <opsw number="23" setting="closed"/>
          </choice>
          <choice name="Motorola Trinary">
            <opsw number="21" setting="thrown"/>
            <opsw number="22" setting="closed"/>
            <opsw number="23" setting="thrown"/>
          </choice>
          <choice name="14 Step mode">
            <opsw number="21" setting="closed"/>
            <opsw number="22" setting="thrown"/>
            <opsw number="23" setting="thrown"/>
          </choice>
          <choice name="28 Step mode">
            <opsw number="21" setting="closed"/>
            <opsw number="22" setting="closed"/>
            <opsw number="23" setting="thrown"/>
          </choice>
          <choice name="28 Step FX mode">
            <opsw number="21" setting="thrown"/>
            <opsw number="22" setting="closed"/>
            <opsw number="23" setting="closed"/>
          </choice>
        </option>

        <option name="Loco Aliasing" >
          <choice name="Enabled">
            <opsw number="25" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="25" setting="closed"/>
          </choice>
        </option>

        <option name="Decoder Assisted Consisting" >
          <choice name="Enabled">
            <opsw number="17" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="17" setting="closed"/>
          </choice>
        </option>

        <option name="Automatic Loco Address Purging" >
          <choice name="Disabled">
            <opsw number="14" setting="closed"/>
          </choice>
          <choice name="200 seconds">
            <opsw number="13" setting="thrown"/>
            <opsw number="14" setting="thrown"/>
          </choice>
          <choice name="600 seconds">
            <opsw number="13" setting="closed"/>
            <opsw number="14" setting="thrown"/>
          </choice>
        </option>

        <option name="Command Station Beeps for Loco Address Purging" >
          <choice name="Enabled">
            <opsw number="42" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="42" setting="closed"/>
          </choice>
        </option>

        <option name="Analog Loco Address 0" >
          <choice name="Enabled">
            <opsw number="20" setting="thrown"/>
          </choice>
          <choice name="Disabled">
            <opsw number="20" setting="closed"/>
          </choice>
        </option>
      </group>

      <group name="Reset" >
        <option name="Reset Memory" >
          <choice name="Don't Reset Memory">
            <opsw number="36" setting="thrown"/>
            <opsw number="37" setting="thrown"/>
            <opsw number="38" setting="thrown"/>
            <opsw number="39" setting="thrown"/>
          </choice>
          <choice name="Mobile Decoder/Consist Info">
            <opsw number="36" setting="closed"/>
          </choice>
          <choice name="Switch Routes">
            <opsw number="37" setting="closed"/>
          </choice>
          <choice name="Locomotice Roster">
            <opsw number="38" setting="closed"/>
          </choice>
          <choice name="All">
            <opsw number="39" setting="closed"/>
          </choice>
        </option>
      </group>
    </options>
  </command-station>

  <command-station name="DB150" >
    <!-- OpSws and Settings that uniquely identify this Command Station -->
    <identifier>
      <opsw number="59" setting="thrown"/>
      <opsw number="60" setting="thrown"/>
      <opsw number="61" setting="closed"/>
    </identifier>

    <!-- Configureable Options for a DB150 -->
    <options>
    </options>
  </command-station>
</digitrax-cs-config>