<?xml version="1.0" encoding="ISO-8859-1"?>
<?xml-stylesheet type="text/xsl" href="../XSLT/decoder.xsl"?>
<!-- Copyright (C) JMRI 2007 All rights reserved -->
<!-- $Id: MRC_soundbrilliance1645.xml 17977 2011-07-18 17:23:46Z zoo $ -->
<!--                                                                        -->
<!-- JMRI is free software; you can redistribute it and/or modify it under  -->
<!-- the terms of version 2 of the GNU General Public License as published  -->
<!-- by the Free Software Foundation. See the "COPYING" file for a copy     -->
<!-- of this license.                                                       -->
<!--                                                                        -->
<!-- JMRI is distributed in the hope that it will be useful, but WITHOUT    -->
<!-- ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or  -->
<!-- FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License  -->
<!-- for more details.                                                      -->
<decoder-config xmlns:xi="http://www.w3.org/2001/XInclude" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://jmri.org/xml/schema/decoder.xsd">
  <version author="Bill Chown" version="3" lastUpdated="20080430"/>
<!-- corrected more typos causing incorrect values -->
  <version author="Bill Chown" version="2" lastUpdated="20080221"/>
  <version author="Michael Dunn" version="1" lastUpdated="20070421"/>
<!-- made from the MRC_1636 file by Paul Bender -->
<!-- version 2 corrected typos causing problems with some CV fields not appearing -->
<!-- version 2 added many decoder-specific tool tips and added CV identities to all tool tips -->
  <decoder>
    <family name="Brilliance Sound Decoders" mfg="MRC" lowVersionID="32" highVersionID="32">
      <model model="Synch Diesel Sound 1645" numOuts="2" numFns="12" maxTotalCurrent="0.75A" extFnsMRC="yes">
        <size length="90" width="14" height="4.2" units="mm"/>
      </model>
    </family>
    <programming direct="yes" paged="yes" register="yes" ops="yes"/>
    <variables>
      <variable label="Short Address" CV="1" comment="Range 1-127" tooltip="Sets the Short, Primary or 2-digit address, CV 1, range 1-127" item="Short Address" default="3">
        <shortAddressVal/>
        <label>Short Address</label>
        <comment>Range 1-127</comment>
      </variable>
      <variable label="Start voltage" CV="2" item="Vstart" default="0" tooltip="sets the motor voltage at Speed Step 1, range 0(default)-32, CV2" comment="Range 0-32">
        <decVal max="32"/>
        <label>Start voltage</label>
        <comment>Range 0-32</comment>
      </variable>
      <variable label="Acceleration" CV="3" item="Accel" default="0" tooltip="Sets the acceleration rate (delay or momentum), range 0(default)-32, CV3" comment="Range 0-32">
        <decVal max="32"/>
        <label>Acceleration</label>
        <comment>Range 0-32</comment>
      </variable>
      <variable label="Deceleration" CV="4" item="Decel" default="0" tooltip="Sets the deceleration rate (delay or momentum), range 0(default)-32, CV4" comment="Range 0-32">
        <decVal max="32"/>
        <label>Deceleration</label>
        <comment>Range 0-32</comment>
      </variable>
      <variable label="Top voltage" CV="5" item="Vhigh" default="32" tooltip="sets the motor voltage at top Speed Step, range 0-32(default), CV5" comment="Range 0-32">
        <decVal max="32"/>
        <label>Top voltage</label>
        <comment>Range 0-32</comment>
      </variable>
      <variable label="Speed curve select" CV="6" item="Speed Table Selection" default="0" tooltip="sets the motor voltage increase curve with Speed Steps, range 0(default)-2, CV6">
        <enumVal>
          <enumChoice choice="Linear" value="0">
            <choice>Linear</choice>
          </enumChoice>
          <enumChoice choice="Slow - increase at slow speed" value="1">
            <choice>Slow - increase at slow speed</choice>
          </enumChoice>
          <enumChoice choice="Fast - increase at fast speed" value="2">
            <choice>Fast - increase at fast speed</choice>
          </enumChoice>
        </enumVal>
        <label>Speed curve select</label>
      </variable>
      <variable label="Manufacturer version number" CV="7" readOnly="yes" tooltip="CV7=32 for all MRC Brilliance models, Read Only" item="Decoder Version" default="32">
        <decVal/>
        <label>Manufacturer version number</label>
      </variable>
      <variable label="Manufacturer ID" CV="8" readOnly="yes" tooltip="CV8=143 for MRC, Read Only" item="Manufacturer" default="143">
        <decVal/>
        <label>Manufacturer ID</label>
      </variable>
      <variable label="Long Address" CV="17" item="Extended Address" tooltip="Sets the Extended (4 digit) address, range 128-9999, mapped to CV17 and 18" comment="4 digit address (Range 0001-9999)">
        <longAddressVal/>
        <label>Long Address</label>
        <comment>4 digit address (Range 0001-9999)</comment>
      </variable>
      <variable label="Advanced consist address" CV="19" mask="XVVVVVVV" item="Consist Address" tooltip="CV19, range 1-127">
        <decVal/>
        <label>Advanced consist address</label>
      </variable>
      <variable label="Consist Direction" CV="19" mask="VXXXXXXX" tooltip="CV19, Normal(default) or Reversed(address+128)">
        <enumVal>
          <enumChoice choice="Normal">
            <choice>Normal</choice>
          </enumChoice>
          <enumChoice choice="Reversed">
            <choice>Reversed</choice>
          </enumChoice>
        </enumVal>
        <label>Consist Direction</label>
      </variable>
      <variable label="Functions Respond to Address" CV="21" mask="XXXXXXXV" tooltip="CV21, least bit">
        <enumVal>
          <enumChoice choice="Locomotive address only">
            <choice>Locomotive address only</choice>
          </enumChoice>
          <enumChoice choice="Respond to consist address">
            <choice>Respond to consist address</choice>
          </enumChoice>
        </enumVal>
        <label>Functions Respond to Address</label>
      </variable>
      <variable label="Normal direction of motion" CV="29" tooltip="CV29, '1' (least significant) bit, Forward(0)(default) or Reverse(1)" mask="XXXXXXXV" item="Locomotive Direction">
        <enumVal>
          <enumChoice choice="Forward">
            <choice>Forward</choice>
          </enumChoice>
          <enumChoice choice="Reverse">
            <choice>Reverse</choice>
          </enumChoice>
        </enumVal>
        <label>Normal direction of motion</label>
      </variable>
      <variable label="Speed Steps" CV="29" mask="XXXXXXVX" tooltip="CV29, '2' bit. Sets the Speed Step for motor, also affects some light settings" item="Speed Step Mode" default="1">
        <enumVal>
          <enumChoice choice="14">
            <choice>14</choice>
          </enumChoice>
          <enumChoice choice="28/128 (recommended)">
            <choice>28/128 (recommended)</choice>
          </enumChoice>
        </enumVal>
        <label>Speed Steps</label>
      </variable>
      <variable label="Analog conversion mode" CV="29" tooltip="CV29, '4' bit. Allows the loco to run on DC, default is Off" mask="XXXXXVXX" default="0" item="Analog (DC) Operation">
        <enumVal>
          <enumChoice choice="Off">
            <choice>Off</choice>
          </enumChoice>
          <enumChoice choice="On">
            <choice>On</choice>
          </enumChoice>
        </enumVal>
        <label>Analog conversion mode</label>
      </variable>
      <variable label="Addressing Mode" CV="29" mask="XXVXXXXX" tooltip="CV29, '32' bit" item="Address Format">
        <enumVal>
          <enumChoice choice="2 digit addressing">
            <choice>2 digit addressing</choice>
          </enumChoice>
          <enumChoice choice="4 digit addressing">
            <choice>4 digit addressing</choice>
          </enumChoice>
        </enumVal>
        <label>Addressing Mode</label>
      </variable>
      <variable label="Horn type" CV="50" item="Sound Option 2" default="4" tooltip="CV50, range 0-16" comment="Range 0-16">
        <decVal max="16"/>
        <label>Horn type</label>
        <comment>Range 0-16</comment>
      </variable>
      <variable label="Horn volume" CV="51" item="Sound Setting 1" default="3" tooltip="CV51, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Horn volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Bell type" CV="52" item="Sound Option 3" default="3" tooltip="CV52, range 0-6" comment="Range 0-6">
        <decVal max="6"/>
        <label>Bell type</label>
        <comment>Range 0-6</comment>
      </variable>
      <variable label="Bell volume" CV="53" item="Sound Setting 2" default="3" tooltip="CV53, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Bell volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Bell ring rate" CV="54" item="Sound Setting 3" default="3" tooltip="CV54, range 0-50" comment="Range 0-50">
        <decVal max="50"/>
        <label>Bell ring rate</label>
        <comment>Range 0-50</comment>
      </variable>
      <variable label="Diesel Rumble volume" CV="55" item="Sound Setting 4" default="3" tooltip="CV55, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Diesel Rumble volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Brake Squeal volume" CV="56" item="Sound Setting 5" default="3" tooltip="CV56, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Brake Squeal volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Dynamic Brake volume" item="Sound Setting 6" CV="57" default="3" tooltip="CV57, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Dynamic Brake volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Air Release volume" item="Sound Setting 7" CV="58" default="3" tooltip="CV58, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Air Release volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Air Pump volume" CV="59" item="Sound Setting 8" default="3" tooltip="CV59, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Air Pump volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Safety Pop Valve volume" CV="60" item="Sound Setting 9" default="3" tooltip="CV60, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Safety Pop Valve volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Engine Cooling Fan volume" CV="61" item="Sound Setting 10" default="3" tooltip="CV61, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Engine Cooling Fan volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Coupling volume" CV="62" item="Sound Setting 11" default="3" tooltip="CV62, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Coupling volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Random Noise volume" CV="63" item="Sound Setting 12" default="3" tooltip="CV63, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Random Noise volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Rail Wheel Clack volume" CV="64" item="Sound Setting 13" default="3" tooltip="CV64, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Rail Wheel Clack volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="User ID #1" CV="105" item="User Id #1" default="0" tooltip="CV105, range 0-255" comment="Range 0-255">
        <decVal max="255"/>
        <label>User ID #1</label>
        <comment>Range 0-255</comment>
      </variable>
      <variable label="User ID #2" CV="106" item="User Id #2" default="0" tooltip="CV106, range 0-255" comment="Range 0-255">
        <decVal max="255"/>
        <label>User ID #2</label>
        <comment>Range 0-255</comment>
      </variable>
      <variable label="Coupling Fire volume" CV="113" item="Sound Setting 16" default="3" tooltip="CV113, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Coupling Fire volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Brake Release volume" CV="114" item="Sound Setting 17" default="3" tooltip="CV114, range 0-3" comment="Range 0-3">
        <decVal max="3"/>
        <label>Brake Release volume</label>
        <comment>Range 0-3</comment>
      </variable>
      <variable label="Auto Brake Squeal" item="Sound Option 5" CV="115" default="1" tooltip="CV115, Off(0) or On(1)(default)">
        <enumVal>
          <enumChoice choice="Off">
            <choice>Off</choice>
          </enumChoice>
          <enumChoice choice="On">
            <choice>On</choice>
          </enumChoice>
        </enumVal>
        <label>Auto Brake Squeal</label>
      </variable>
      <variable label="Coupling Sound Type" item="Sound Option 6" CV="116" default="1" tooltip="CV116, Off(0) or Type1(1)(default) or Type2(2)">
        <enumVal>
          <enumChoice choice="Off">
            <choice>Off</choice>
          </enumChoice>
          <enumChoice choice="Type 1">
            <choice>Type 1</choice>
          </enumChoice>
          <enumChoice choice="Type 2">
            <choice>Type 2</choice>
          </enumChoice>
        </enumVal>
        <label>Coupling Sound Type</label>
      </variable>
      <variable label="Diesel notch mode" item="Sound Option 7" CV="122" default="1" tooltip="CV122, Off(0) or Auto(1)(default) or Linear(2) or Manual(3)">
        <enumVal>
          <enumChoice choice="Off" value="0">
            <choice>Off</choice>
          </enumChoice>
          <enumChoice choice="Auto notch - RPM and notch synchro to speed" value="1">
            <choice>Auto notch - RPM and notch synchro to speed</choice>
          </enumChoice>
          <enumChoice choice="Linear notch - RPM synchro to speed" value="2">
            <choice>Linear notch - RPM synchro to speed</choice>
          </enumChoice>
          <enumChoice choice="Manual notch - notch up/down with F8/F9" value="3">
            <choice>Manual notch - notch up/down with F8/F9</choice>
          </enumChoice>
        </enumVal>
        <label>Diesel notch mode</label>
      </variable>
      <variable label="Prime Mover sound" item="Sound Option 8" CV="123" default="0" tooltip="CV123, SD45-2(0)(default) or MP-15(1)">
        <enumVal>
          <enumChoice choice="SD45-2" value="0">
            <choice>SD45-2</choice>
          </enumChoice>
          <enumChoice choice="MP-15" value="1">
            <choice>MP-15</choice>
          </enumChoice>
<!-- Note per Mfg. recorded sounds ARE NOT for GE P42 or EMD E8/E9! -->
<!-- these sounds are named as EMD large diesel, EMD switcher -->
        </enumVal>
        <label>Prime Mover sound</label>
      </variable>
    </variables>
    <resets>
      <factReset label="Reset All CVs" CV="125" default="1"/>
    </resets>
  </decoder>
  <pane name="MRC">
    <column>
      <label label="MRC 1645 fits Kato E9 and P42 wide body style locos">
        <label>MRC 1645 fits Kato E9 and P42 wide body style locos</label>
      </label>
      <label label="MRC notes the recorded sounds differ from these models">
        <label>MRC notes the recorded sounds differ from these models</label>
      </label>
      <label label=" ">
        <label> </label>
      </label>
      <separator/>
      <label label=" ">
        <label> </label>
      </label>
      <display item="Functions Respond to Address"/>
    </column>
    <name>MRC</name>
  </pane>
</decoder-config>